Cybex 50L Console Software Update Procedure
Procedure 1: USB Installation Instructions – Console
1. Execute step (a) if executing on a wall-powered unit or step (b) if executing on a battery powered unit
b. If Battery-Powered: Start pedaling or press the “Start” button to wake the unit up. Then maintain at least a minimum of 60 RPMs for the upgrade duration, ~5 – 7 minutes. Power up the unit and wait until the unit is idle, in the attract state.
2. Insert the USB stick with " cybex50l.lfupd " installed
3. Push the following keys in the order and about one second apart:
b. Time (clock icon)
4. Upgrade process will be indicated by numbers increasing on both sides of the console. Approximate time is 1 – 2 minutes.
5. A check mark shown in the middle indicates that the upgrade is a success.
6. To check the software version, push the following keys in the order below, about one second apart (the software version matches this release version number):
7 . Remove USB stick and operations may resume.
Procedure 2: Resistance Control Board (RCB) using an attached console
1. Execute step (a) if executing on a wall-powered unit or step (b) if executing on a batterypowered unit
b. If Battery-Powered: Start pedaling or press the “Start” button to wake the unit up. Then maintain at least a minimum of 60 RPMs for the upgrade duration, ~5 – 7 minutes. Power up the unit and wait until the unit is idle, in the attract state.
2. Insert the USB stick with " cybex50l.lfupd " installed
3. Push the following keys in the order and about one second apart:
b. Time (clock icon)
4. Upgrade process will be indicated by numbers increasing on both sides of the console. Approximate time is 1 – 2 minutes.
5. A check mark shown in the middle indicates that the upgrade is a success.
6. To check the software version, push the following keys in the order below, about one second apart (verify software version matches this release version number):
b. Press the workout stop button
7. Remove USB stick and operations may resume.